- Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese)
- Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom
-
- Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe
-
Acti 9 Smartlink, 11 Kanäle, Modbus RS485, E/A-Kommunikationsmodul
A9XMSB11
Materialpreisgruppe : D3
372,00 EUR
EAN Code: 3606480430602
Hauptdokumente
Produktdatenblatt | Download |
Umweltzertifikat (ROHS/REACH) | Download |
Entsorgungsinformation | Download |
Sonstiger technischer Leitfaden | Download |
Anwendungshinweise | Download |
Leistungsbeschreibung | Download |
CAD | Download |
Katalog | Download |
Produktumweltprofil | Download |
Gebrauchsanleitung | Download |
Konformitätserklärung | Download |
Firmware - History, Utility & Others | Download |
Benutzerhandbuch | Download |
Spezifikationen
Hauptmerkmale | |
---|---|
Produktsortiment | EcoStruxure |
Produktname | EcoStruxure I/O Smart Link |
Produkt- oder Komponententyp | Smart-Kommunikationsmodul |
Kurzbezeichnung des Geräts | I/O Smart Link |
Anwendungstyp | Laststeuerung Überwachung des Leistungsschalterstatus Grundlegende Energiemessung E |
Maximale Anzahl an angeschlossenen Geräten | Bis zu 11 verdrahtete Geräte |
Kanalgruppe | 1 Gruppe aus 11 digitalen Kanälen |
Max. Versorgungsstrom | 1,5 A |
Nennhilfsspannung [UH,nom] | 24 V DC +/-20 % |
Konnektivität mit Geräten | Digitaler Eingang und Ausgang Impulsausgangszähler |
Kommunikationsdienst | Modbus server für RS485 |
Webserver | Kompatibel mit GMS-Controller |
Webdienste | Webseite | Zusatzmerkmale |
anwendungspezifischer E/A | Impuls-Summenzähler Pulswechselrichter |
Schutzfunktionen | Gegen Verpolung für Hilfsspannungsversorgung Gegen Verpolung für Eingang Überspannung bei 33 V DC für digitaler Ausgang |
Störfestigkeit gegen Unterbrechungen | 10 ms |
Rückstellung | Werksreset auf Vorderseite Muffen-Drucktaste By address encoder By plug in, plug out the power supply |
Eingangs-/Ausgangstyp | 2 Eingänge + 1 Ausgang pro digitalem Kanal |
Eingangstyp | Stromkörper für Digitaleingang, 24 V DC +/-20 % bei 2,5 mA |
max. Dauerstrom | 5 mA für Digitaleingang |
Zeit für elektronisches Filtern | 2 ms for Digitaleingang von Zustand 0 bis Zustand 1 |
Ausgangstyp | Logik-Stromquelle: 24 V - DC - 100 mA |
Maximaler Spannungsabfall | <1 V bei Status 1 digitaler Ausgang |
Einschaltstrom | 0,5 A für digitaler Ausgang 7 A für Stromversorgung |
Lokale Signalisierung | Kommunikation: 1 LED (gelb) Status: 1 LED (grün, orange und rot) |
Typ Einstellung | Modbus-Adresse 01 - 99 für Adressengeber Rückstellung für Adressengeber Rückstellung für Hilfsstromversorgung einstecken/ausstecken |
Einbauposition | Horizontal und vertikal auf DIN-Schiene |
Farbe | Weiß (RAL 9003) |
Position des Anschlusses | Frontseite |
Anschlüsse - Klemmen | Federzugklemme Ti24 qty: 11 for Digitaler Eingang/Ausgang, separat zu bestellen Steckverbinder qty: 1 for Versorgungsstromkreis Steckverbinder qty: 1 for Kommunikationsbus |
Klemmverbindungskapazität | 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), flexibel mit Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), flexibel ohne Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), fest mit Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), fest ohne Kabelende für Kommunikationsbus 1 x 0,2-1 x 1,5 mm², flexibel mit Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², flexibel ohne Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², fest mit Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², fest ohne Kabelende für Steuerung 2 x 0,2 - 1,5 mm², flexibel mit Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², flexibel ohne Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², fest mit Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², fest ohne Kabelende für Versorgungsstromkreis |
Drahtabisolierungslänge | Steuerung: 10 mm Versorgungsstromkreis: 7 mm Kommunikationsbus: 7 mm |
Kommunikationsnetztyp | RS485 Modbus RTU Client/Server SUB-D 9 4800,9600,19200 bps, 38,4 Kbps |
9 mm Polmittenabstand | 0 nützlich |
Höhe | 22,5 mm |
Breite | 359 mm |
Tiefe | 42 mm |
Produktgewicht | 188 g |
geliefertes Zubehör | Satz à 1 Busverbinder Satz à 1 Netzstecker Satz à 2 Verriegelungsclips |
Kompatible Produktfamilie | Acti 9 iTL Zusatzausrüstung Linergy Linergy FM Acti 9 iOF+SD 24 Acti 9 iACT24 Acti 9 iATL24 PowerLogic Impulsausgangszähler Acti 9 RCA iC60 Acti 9 Acti9 iCT Zusatzausrüstung Acti 9 Acti9 iC60 Acti 9 Acti9 iID Acti 9 Acti9 iSW-NA Acti 9 Acti9 iDPN Vigi Acti 9 Acti 9 C40 Multi 9 Multi9 C60 Acti 9 Acti 9 DT40 Acti 9 Acti9 DT60 Acti 9 Acti 9 I-NA Acti 9 Acti 9 ITG40 Acti 9 Acti 9 iDPN Acti 9 Acti9 Reflex iC60 Ti24 Stecker |
Inbetriebnahme-Schnittstelle | EcoStruxure Power Commission Webseite |
Marktsegment | Gebäude Kleingewerbe |
Kompatibilitätscode | Acti 9 Smartlink | Montage |
Schutzart (IP) | IP20 |
Verschmutzungsgrad | 3 |
elektromagnetische Verträglichkeit | Widerstandsfähigkeit gegen elektrostatische Entladung (Luftaustritt), Klasse B, 8 kV, conforming to IEC 61000-4-2 Widerstandsfähigkeit gegen elektrostatische Entladung (Kontaktentladung), Klasse B, 4 kV, conforming to IEC 61000-4-2 Beständigkeit gegenüber ausgestrahlten Magnetfeldern (80 MHz - 3 GHz), Klasse A, 10 V/m, conforming to IEC 61000-4-3 Stromversorgung: Beständigkeit gegenüber ausgestrahlten Magnetfeldern (1.4…6 GHz), Klasse A, 3 V/m, conforming to IEC 61000-4-3 Stromversorgung: Festigkeit gegen Störimpuls (5 - 100 kHz), Klasse B, 2 kV, conforming to IEC 61000-4-4 Ein-/Ausgang: Festigkeit gegen Störimpuls, Klasse B, 1 kV, conforming to IEC 61000-4-4 Kommunikationsbus: Festigkeit gegen Störimpuls (0,15 - 80 MHz), Klasse B, 1 kV, conforming to IEC 61000-4-4 Leitungsgebundene elektromagnetische Verträglichkeit (0,15 - 80 MHz), Klasse A, 3 V, conforming to IEC 61000-4-6 Leitungsgebundene Emission (0,15 - 30 MHz), Klasse B, conforming to IEC 61326-1 Leitungsgebundene Emission (0,15 - 30 MHz), Klasse B, conforming to CISPR 11 Abgestrahlte Emission (30...6000 MHz), Klasse B, conforming to IEC 61326-1 Abgestrahlte Emission (30...6000 MHz), Klasse B, conforming to CISPR 11 Stromversorgung: Stoßspannungen (DM coupling 42 Ohm), Klasse B, 1 kV, conforming to IEC 61000-4-5 Stromversorgung: Stoßspannungen (CM coupling 42 Ohm), Klasse B, 2 kV, conforming to IEC 61000-4-5 Kommunikationsbus: Stoßspannungen (CM coupling 2 Ohm), Klasse B, 1 kV, conforming to IEC 61000-4-5 |
Umgebungseigenschaften | Korrosiv 3C2 entspricht IEC 60721-3-3 Salznebel 2 entspricht IEC 60068-2-52 |
Vibrationsfestigkeit | 1 gn, Amplitude = 3,5 mm (f = 5…300 Hz)10 Zyklen entspricht EN/IEC 60068-2-6 |
Stoßfestigkeit | 15 gn für 11 ms entspricht IEC 60068-2-27 |
Feuerbeständigkeit | Andere Bauteile: 650 °C ( 30 s ) entspricht IEC 60695-2-10 Auf Anschlussklemmen: 960 °C ( 30 s ) entspricht IEC 60695-2-10 |
Tropentauglichkeit | 2 |
Relative Luftfeuchtigkeit | 0…93 % bei 40 °C |
Aufstellungshöhe | 0 - 2.000 m |
Umgebungstemperatur bei Betrieb | -25…60 °C |
Umgebungstemperatur bei Lagerung | -40…85 °C |
Schutzart (IK) | IK06 entspricht IEC 62262 |
Normen | IEC 61010-2-201 IEC 61010-1 | Verpackungseinheiten |
VPE 1 Art | PCE |
VPE 1 Menge | 1 |
VPE 1 Gewicht | 271,0 g |
VPE 1 Höhe | 3,4 cm |
VPE 1 Breite | 6,4 cm |
VPE 1 Länge | 36,4 cm |
VPE 2 Art | S03 |
VPE 2 Menge | 32 |
VPE 2 Gewicht | 9,063 kg |
VPE 2 Höhe | 30,0 cm |
VPE 2 Breite | 30,0 cm |
VPE 2 Länge | 40,0 cm | Vertragliche Gewährleistung |
Garantie | 18 months |
Nachhaltigkeit
Mit der Kennzeichnung Green PremiumTM verpflichtet sich Schneider Electric für die Lieferung von Produkten mit erstklassiger Umweltleistung. Green Premium verspricht die Einhaltung aktueller Vorschriften, Transparenz in Bezug auf Umweltauswirkungen sowie Wiederverwertbarkeit und Produkte mit niedrigem CO2-Fußabdruck.
NachhaltigkeitAngebotsstatus nachhaltiges Produkt | Green Premium Produkt |
EU-RoHS-Richtlinie | Übererfüllung der Konformität (außerhalb EU RoHS-Scope) |
43 Dokumente
A9XMSB11 REACh-Erklärung 19/04/24 · Umweltzertifikat (ROHS/REACH) | 0,2 MB | Download |
A9XMSB11 China-RoHS-Erklärung 19/04/24 · Umweltzertifikat (ROHS/REACH) | 0,2 MB | Download |
A9XMSB11 EU-RoHS-Erklärung 19/04/24 · Umweltzertifikat (ROHS/REACH) | 0,2 MB | Download |
EcoStruxure I/O Smart Link - Guida utente DOCA0302IT · 15/04/24 · Benutzerhandbuch | 4,4 MB | Download |
EcoStruxure I/O Smart Link - Guía de usuario DOCA0302ES · 15/04/24 · Benutzerhandbuch | 4,4 MB | Download |
EcoStruxure I/O Smart Link - Manuel utilisateur DOCA0302FR · 15/04/24 · Benutzerhandbuch | 4,4 MB | Download |
EcoStruxure I/O Smart Link - Notes de publication du logiciel embarqué 15/04/24 · Firmware - History, Utility & Others | 0,2 MB | Download |
EcoStruxure I/O Smart Link - Notas de la versión del firmware 15/04/24 · Firmware - History, Utility & Others | 0,2 MB | Download |
EU Declaration of Conformity 15/04/24 · Konformitätserklärung | 0,5 MB | Download |
UK Declaration of conformity 15/04/24 · Konformitätserklärung | 0,2 MB | Download |
EcoStruxure I/O Smart Link - User Guide DOCA0302EN · 15/04/24 · Benutzerhandbuch | 4,4 MB | Download |
EcoStruxure I/O Smart Link - A9XMSB11 - Gebrauchsanleitung PKR55093 · 15/04/24 · Gebrauchsanleitung | 12,7 MB | Download |
EcoStruxure I/O Smart Link - Firmware Release Notes 15/04/24 · Firmware - History, Utility & Others | 0,2 MB | Download |
DoC DEcomm interfaces 15/04/24 · Konformitätserklärung | 1,0 MB | Download |
Acti 9 Smartlink - product environmental profile 15/04/24 · Produktumweltprofil | 0,5 MB | Download |
Auswahlkatalog 2024 15/04/24 · Katalog | 47,5 MB | Download |
Acti9 Smartlink Modbus - CAD model - 3D CAD 15/04/24 · CAD | 2,9 MB | Download |
Diagnostic du Système de Communication Acti9 - Manuel utilisateur DOCA0042FR · 15/04/24 · Benutzerhandbuch | 0,7 MB | Download |
Sistema de comunicación Acti9 Smartlink Ethernet - Manual del usuario DOCA0073ES · 15/04/24 · Benutzerhandbuch | 20,2 MB | Download |
Sistema di comunicazione Acti9 Smartlink Modbus - Manuale utente DOCA0004IT · 15/04/24 · Benutzerhandbuch | 11,3 MB | Download |
Sistema di comunicazione Acti9 Smartlink Ethernet - Manuale utente DOCA0073IT · 15/04/24 · Benutzerhandbuch | 20,0 MB | Download |
Système de communication Acti9 Smartlink Modbus - Manuel utilisateur DOCA0004FR · 15/04/24 · Benutzerhandbuch | 11,3 MB | Download |
Sistema de comunicaciones Acti9 Smartlink Modbus - Manual del usuario DOCA0004ES · 15/04/24 · Benutzerhandbuch | 11,6 MB | Download |
Acti9 Système de communication Smartlink Ethernet - Manuel d’utilisation DOCA0073FR · 15/04/24 · Benutzerhandbuch | 20,5 MB | Download |
Système PowerTag - Guide de conception et de mise en service DOCA0194FR · 15/04/24 · Benutzerhandbuch | 14,2 MB | Download |
Katalog 2021 ComPacT NSX & NSXm ZXKCOMPACT · 15/04/24 · Katalog | 44,7 MB | Download |
Installationsgeräte ZXKACTI9 · 15/04/24 · Katalog | 36,5 MB | Download |
A9XMSB11 - Technical Product Datasheet A9XMSB11_DB · 15/04/24 · Leistungsbeschreibung | 0,1 MB | Download |
Acti9 Smartlink Modbus - User Manual DOCA0042EN · 15/04/24 · Benutzerhandbuch | 0,7 MB | Download |
Acti9 Smartlink Ethernet Communication System - User Manual DOCA0073EN · 15/04/24 · Benutzerhandbuch | 19,3 MB | Download |
PowerTag System - Design and Commissioning Guide DOCA0194EN · 15/04/24 · Benutzerhandbuch | 14,4 MB | Download |
Acti 9 Smartlink Modbus Communication System - User Manual DOCA0004EN · 15/04/24 · Benutzerhandbuch | 11,2 MB | Download |
Kommunikationssystem Acti9 Smartlink Modbus Benutzerhandbuch DOCA0004DE · 15/04/24 · Benutzerhandbuch | 11,1 MB | Download |
PowerTag System – Leitfaden für die Planung und Inbetriebnahme DOCA0194DE · 15/04/24 · Benutzerhandbuch | 2,5 MB | Download |
Kommunikationssystem Acti9 Smartlink Ethernet - Benutzerhandbuch DOCA0073DE · 15/04/24 · Benutzerhandbuch | 20,2 MB | Download |
Acti 9 Smartlink - A9XMSB11- Gebrauchsanleitung S1B33423 · 15/04/24 · Gebrauchsanleitung | 6,2 MB | Download |
Smart panels - communication switchboards assembly - technical guide 15/04/24 · Sonstiger technischer Leitfaden | 55,5 MB | Download |
EU Declaration - FD16051101A Acti 9 Smartlink A9XMEA08 15/04/24 · Konformitätserklärung | 0,3 MB | Download |
EcoStruxure I/O Smart Link - Note della versione del firmware 15/03/24 · Firmware - History, Utility & Others | 0,2 MB | Download |
EcoStruxure I/O Smart Link - Benutzerhandbuch DOCA0302DE · 15/03/24 · Benutzerhandbuch | 4,4 MB | Download |
EcoStruxure I/O Smart Link - Firmware-Versionshinweise 19/02/24 · Firmware - History, Utility & Others | 0,2 MB | Download |
Ensuring the satisfactory functioning of loads critical for human protection 23/01/24 · Anwendungshinweise | 0,3 MB | Download |
Acti 9 Smartlink, Circularity Profile, End of Life Instructions 15/01/24 · Entsorgungsinformation | 0,4 MB | Download |